Description
Model | A-200AF-5-5 | ||
---|---|---|---|
8 | |||
Input | Voltage Range | 180~264VAC | |
Input Current | 230VAC/2.5A | ||
Efficiency | ≥83% | ≥88% | |
Frequency Range | 47~63HZ | ||
Leakage Current | <3.5mA/240VAC | ||
Inrush Current | Cold Start 45A/230VAC | ||
Output | DC Voltage | 2.8V | 5V |
Rated Current | 40A | 40A | |
Power | 112W | 200W | |
Voltage Adj.Range | ±3.0% | ±3.0% | |
Ripple And Noise | 150mVp-P | 150mVp-P | |
Set Up,Rise Time | 2000ms,50ms/(230VAC) 100% Load | ||
Hold Up Time | 20ms/230VAC 100% Laod | ||
Line Regulation | ±0.5% | ±0.5% | |
Load Regulation | ±2.0% | ±2.0% | |
Voltage Tolerance | ±2.0% | ±2.0% | |
EMC | EMS | Design Refer To:EN55024 ;EN61000-4-2,3,4,5,6,8,11 | |
Harmonic Current | Design Refer To:GB17625.1;EN61000-3-2,-3 | ||
EMC | Design Refer To:EN55022,Class A | ||
Safety | Safety Standard | Design Refer To:GB4943/UL1012 | |
Withstand Voltage | I/P-O/P:1.5KVac/10mA; I/P-CASE:1.5KVac/10mA; O/P-CASE:0.5KVAC/10mA Testing Time:1min | ||
Isolation Resistance | I/P-O/P:100M Ohms; I/P-Case:100M Ohms; O/P-Case:100M Ohms | ||
Protection | Over Voltage | / | |
Over Load | 110~150% Rated Hiccup Mode, Recovers Automatically After Fault Condition Is Removed | ||
Over Temperature | / | ||
Short Circuit | Hiccup Mode, Recovers Automatically After Fault Condition Is Removed | ||
Environment | Working Temperature And Humidity | -30~70℃ 20%~95%RH No Condensing (Refer To Derating Curve) | |
Storage Temperature And Humidity | -40℃~85℃; 10%~95%RH No Condensing | ||
Vibration | Frequency Range 10 ~ 500Hz,Acceleration 2G, Each Sweep Cycle For 10min, 6 Sweep Cycles Along X, Y, Z Axis | ||
Shock | Acceleration: 20g, Duration: 11ms, 3 Impacts Along X, Y, Z Axis | ||
Altitude | 2000mtrs(For Every 100 M Higher Than 2000 M, The Ambient Temperature Decreases By 0.6 ℃) | ||
Reliability | MTBF | 25℃:250000Hrs, MIL-217 Method | |
Others | Size | 208*59*31 Mm(L*W*H) | |
Packing | 0.45Kg/Piece,30pieces/Carton,15.5KG/Carton | ||
Cooling Mode | ☑ Free Air □ Fan | ||
Extension Mode | Three Proofings Terminal Cover Low Temperature Start(-40℃) Others | ||
Note | *In Order To Extend The Lifetime, It Is Recommended To Configure The Load More Than 30% Of The Remaining Allowance. For Example: The Power Of The Device Requires 100W, Then Use The Power Of Not Less Than 130W. *Ripple Test Method: 20MHz Oscilloscope In Power Output Terminal Test, Oscilloscope Probe Wire Length Is Not More Than 12mm, And Input Parallel 47uF Electrolytic Capacitors And 0.1uF High Frequency Capacitance Probe. *All Electrical Performance Tests Are Performed At 25 C. *When The Product Is Used In Full Load, The Aluminum Plate With An Area Of 400 * 400 * 3mm Shall Be Added For Auxiliary Heat Dissipation. *The Power Supply Is A Part Of The Components Of The Equipment System. All EMC Tests Are Conducted By |