Description
Model | CV-300RF-5 | CV-300RF-12 | CV-300RF-24 | CV-300RF-36 | CV-300RF-48 | ||
---|---|---|---|---|---|---|---|
Output | DC Voltage | 5V | 12V | 24V | 36V | 48V | |
Rated Current | 60A | 25A | 12.5A | 8.4A | 6.3A | ||
Current Range | 0~60A | 0~25A | 0~12.5A | 0~8.4A | 0~6.3A | ||
Rated Power | 300W | 300W | 300W | 302W | 302W | ||
Ripple & Noise | 120mVp-P | 120mVp-P | 150mVp-P | 200mVp-P | 200mVp-P | ||
Voltage Regulation Range | ±10% | ±10% | ±10% | ±10% | ±10% | ||
Voltage Regulation Range | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||
Line Adj Rate | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ||
Load Adj Rate | ±2% | ±1% | ±1% | ±1% | ±1% | ||
Rise | 500ms,50ms/230VAC 100% Load | ||||||
Hold Up Time(Typ) | 20ms/230VAC 100% Load | ||||||
Input | Voltage Range | 176~264V AC | |||||
Frenquency Range | 47~63HZ | ||||||
PFC (Typ) | PF≥0.5 | ||||||
Efficiency(Typ) | ≥75% | ≥80% | ≥82% | ≥83% | ≥84% | ||
Alternating Current | 220VAC | 3.5A | 3.5A | 3.4A | 3.4A | 3.3A | |
In Rush Current(Typ) | 40A/230VAC | ||||||
Leakage Current | <3.5mA/240VAC | ||||||
Protect Ions | Over Load | 110~150% Rated | |||||
Short Circuit | Protection After Short Circuit | ||||||
Overvoltage (Limit Voltage) | 5.6~7V | 13.8~16V | 27.6~32.4V | 41.4~48.6V | 55~62V | ||
Envirom Ent | Working Temp. | -20℃~+50℃ (Refer To Temperature Derating Curve) | |||||
Working Humidity | 20~90%RH Non Condensing | ||||||
Storage Temp. | -30℃~+85℃ | ||||||
Storage Humidity | 10~95% Non Condensing | ||||||
Temp. Coefficiency | ±0.03%/℃(0~50℃) | ||||||
Vibration Resistance | 10~500Hz,2G,10min/Cycle,X、Y、Z 60min In Each Direction | ||||||
Safety | Safety Standards | Design Refer To GB4943-2001,UL1012 | |||||
Withstand Voltage | I/P-O/P、I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||||
Isolation Resistance | I/P-O/P、I/P-FG、O/P-FG:>50MΩ/500VDC | ||||||
EMC | Design Refer To GB9254,EN55022 Class A | ||||||
Harmonic Current | Design Refer To GB17625.1-1998 | ||||||
Others | Lifetime | 100,000 Hours(25℃) | |||||
Size | 240*158*70mm(L*W*H) | ||||||
Weight | 12pc/Ctn | ||||||
Remark | *In Order To Extend The Lifetime, It Is Recommended To Configure The Load More Than 30% Of The Remaining Allowance. For Example: The Power Of The Device Requires 100W, Then Use The Power Of Not Less Than 130W. *Ripple Test Method: 20MHz Oscilloscope In Power Output Terminal Test, Oscilloscope Probe Wire Length Is Not More Than 12mm, And Input Parallel 47uF Electrolytic Capacitors And 0.1uF High Frequency Capacitance Probe. * The Power Supply Is Regarded As Part Of The Internal Components Of The Equipment, And It Needs To Be Combined With The Terminal Equipment To Complete The EMC Related Test And Confirmation. |